HY-ALERTA™ 1600 Intrinsically Safe Area Hydrogen Monitor

H2scan's 2620 Explosion Proof Area Hydrogen Monitor provides hydrogen-specific leak detection and measurement for hydrogen concentrations as low as 4000 ppm and can be scaled to any concentration up to 5% hydrogen by volume, a range representing 10% to 125% of hydrogen's low flammability limit. The monitor is designed for either ceiling or wall mount. H2scan's hydrogen-specific sensor technology has no cross sensitivity to other combustible gases, thus eliminating false positive alarms and ensuring safety system reliability.
HY-ALERTA™ 1600
HY-ALERTA™ 1600 Intrinsically Safe Area Hydrogen Monitor

Performance:
  • Hydrogen Sensitivity Range: 0.4% to 5% hydrogen by volume, 10% to 125% hydrogen lower flammable limit
  • Accuracy: ± (0.03 x indication + 0.2) percent hydrogen by volume
  • Typical Response Time: T90 of 60 sec maximum
  • Ingress Protection: IP64 capable
  • Calibration Interval: 90 days
  • Product Life Expectancy: 10 years

Interface Options:
  • Power Barrier Input Voltage: 24 VDC nominal
  • Power Barrier Input Voltage Range: 20 VDC to 28 VDC
  • Intrinsically Safe Sensor Input Voltage: 10 VDC
  • Sensor Input Voltage Range: 5 VDC to 28 VDC
  • Input Power: 10 W
  • Analog Output: 4 mA to 20 mA
  • Serial Communication: RS422

Dimensions:
  • Total Length: 8.1 in.
  • Total Width: 4.4 in.
  • Depth: 1.6 in.

Operating Conditions:
  • Operating Humidity: 0% to 95% RH
  • Operating Temperature Range: -20șC to 40șC
  • Storage Temperature Range: -40șC to 50șC
  • Calibration Background Gas: Air

Included Accessories:
  • Intrinsically Safe Power Barrier
  • Armored Power / Analog Cable: 4 m
  • Calibration Cup