Carbon Dioxide Adsorbers - VCD-SERIES

The VCD-Series carbon dioxide adsorbers are designed to remove CO2from compressed air. The carbon dioxide adsorber does this by using media beds featuring 13X molecular sieve in a pressure swing adsorption process. Adsorbed moisture and CO2 are vented to atmosphere while dry CO2-free air is provided at the outlet port. Standard voltage is 115 VAC. 230 VAC is available. Standard operating pressures from 3,4 to 10 Bar.

VCD-SERIES CO2 ADSORBER SPECIFICATIONS

Outlet Flow Capacities at Various Operating Pressures

Model Outlet Flow (liters/minute)
Bar 3,4* 4,1* 4,8* 5,5* 6,2 6,9 7,6 8,3* 9,0 9,6 10
VCD3 5 9 13 15 19 23 25 30 33 35 38
VCD4 16 26 33 37 48 60 65 73 85 93 99
* factory selected purge orifice installed for these pressures - please state operating pressure with order
Model VCD3 VCD4
Flows at 6,9 Bar (liters/minute)
Inlet Flow 40 95
Purge Flow 17 35
Outlet Flow 23 60
ALL MODELS
Power requirement: 115/1/50/60 or 220/1/50/60, 20 watts
Maximum temperature 49°C ambient
Maximum pressure 10 Bar
Outlet CO2 concentration: less than 1 PPM
Outlet H2O concentration less than 1 PPM (-73°C dew point)
RECOMMENDED FILTRATION ON INLET
Lubricated Compressor: 5.0 Micron filter and 0.01 Micron filter
Non-lubricated Compressor: 5.0 Micron filter

Connections (NPT)
Inlet 1/4" 1/4"
Outlet 1/4" 1/4"
Dimensions (cm)
Height - "A" 41 61
Width 20 20
Depth 12 12
Weight (kg) 4,1 6,3

FEATURES
  • Outlet CO2 content to less than 1 PPM
  • Outlet H2O content to less than ( -73°C dew point)
  • Air dried to less than -73°C dew point
  • Compact and lightweight design requires less space
  • Solid state timer with built-in memory for energy savings come standard
  • NEMA 1 Electrical
  • Purge mufflers and power cord come standard

TYPICAL APPLICATIONS
  • TOC Analyzers
  • Continuous Emissions Monitoring Systems
  • Environmental Instruments
  • FTIR Spectrometers
  • Gas Chromatographs
  • Laboratory Analyzers

DOWNLOADS