House and Area Gas Purifiers

Gas Purifiers
   
MegaTorr PS7 Series Hydrogen Gas Purifiers (Getter only)

MegaTorr PS7 Hydrogen Gas Purifier

The getter only approach is ideal for facilities that already have a good quality hydrogen supply, but require ultra-high purity (UHP) quality hydrogen for critical processes.
The MegaTorr PS7 Series Heated Getter Hydrogen Gas purifiers utilize a heated getter process to provide ultra-high purity (UHP) gas. This simplified approach provides outlet impurity levels to < 1 ppb for O2, CO, CO2, H2O, CH4, and N2.
This purifier series is provided in three sizes flows up to 20, 40, and 100 Nm3/hr. Getter column replacement can be performed in the field by an authorized SAES Field Service Engineer.

MegaTorr PS7 Getter Only Hydrogen Purifiers
ModelFlow RateDimensionsOutlet
PS7-MGT20-H20 Nm3/hr203 x 119 x 119 cm
(80'' x 47'' x 47'')
common to all:
H2O< 1 ppb
O2< 1 ppb
CO< 1 ppb
CO2< 1 ppb
N2< 1 ppb
CH4< 1 ppb
contact factory
for further details
PS7-MGT40-H40 Nm3/hr203 x 117 x 117 cm
(80'' x 46'' x 46'')
PS7-MGT100-H100 Nm3/hr198 x 132 x 160 cm
(78.6'' x 52'' x 63'')
*all models above are designated with a -S7 suffix

Standard Features:
  • Automated Microprocessor Controller
  • HMI (Human Machine Interface)
  • Password Protected Control System
  • System Alarms
  • Temperature Interlocks
  • N2 Purged Secondary Enclosure
  • H2 Leak Detection Sensor
  • Vented Cabinet Purge
  • Over Pressurization Safety Relief System
  • Electric Gas Preheater
  • Dual Closed-Loop Temperature Controls
  • Redundant Heating Elements
  • Pressure Transducers
  • Battery Back-up
  • Back-up Pneumatics Reservoir
  • Water Cooled Heat Exchanger
  • All Metal Enclosure With Doors
Customer Interface Connections:
  • Alarm Relay - fail safe relay contacts allow remote detection of alarm condition.
  • Remote Contact Shutdown - allows remote shutdown of the purifier.
Optional Equipment:
  • Auto or Manual Bypass
  • Mass flow meter with 4-20mA Output
  • Separate Control Power
  • UPS - Uninterruptible Power Supply
  • MODBUS Data Communication Port
© 2011 Rainer Lammertz