Hydrogen Bulk Gas Purifier - PS7-G - Getter Bed Only (6.0N Hydrogen Required)

MegaTorr PS7 Hydrogen Gas Purifier

The getter only Hydrogen Purifier is ideal for facilities that have a 6.0N (99.9999%) quality hydrogen supply, and require N2 and CH4 removal.
The MegaTorr PS7-G Series Heated Getter Hydrogen Gas purifiers utilize a heated getter process to provide ultra-high purity (UHP) gas. This simplified approach provides outlet impurity levels to < 1 ppb for O2, CO, CO2, H2O, CH4, and N2. Getter column replacement can be performed in the field by an authorized SAES Field Service Engineer. The getter bed only Hydrogen Purifier requires 6.0N H2 (99.9999%). If your quality is lower than 6.0N please see the Adsorber and Getter Hydrogen Purifier.

Standard Features:
  • Automated Microprocessor Controller
  • HMI (Human Machine Interface)
  • Password Protected Control System
  • System Alarms
  • Temperature Interlocks
  • Purged Secondary Enclosure
  • Leak Detection Sensor
  • Vented Cabinet Purge
  • Over Pressurization Safety Relief System
  • Electric Gas Preheater
  • Dual Closed-Loop Temperature Controls
  • Redundant Heating Elements
  • Pressure Transducers
  • Battery Back-up
  • Back-up Pneumatics Reservoir
  • Water Cooled Heat Exchanger
  • All Metal Enclosure With Doors
Optional Features:
  • Auto or Manual Bypass
  • Mass flow meter with 4-20mA Output
  • Separate Control Power
  • UPS - Uninterruptible Power Supply
  • MODBUS Data Communication Port

PS7 Adsorber Only - Performance
Gases PurifiedImpurities RemovedOutlet Performance
H2H2O, O2, CO, CO2, N2< 1 ppb
CH4, NMHC<< 10 ppb (at factory), <1 ppb (on-site)

PS7 Specifications
ModelMaximum Flow
(Nm3/hr)
Average Power
Consumption (kW)
Maximum Pressure Drop
(bar)
Dimensions (cm)Weight
(kg)
HWD
PS7-MGT10-H-G101,90,7205118120<772
PS7-MGT20-H-G203,80,7205118120<772
PS7-MGT40-H-G407,50,7205118120<772
PS7-MGT100-H-G10020,51213134164<998