House and Area Gas Purifiers

Gas Purifiers
   
MegaTorr PS6 Series Catalytic Oxygen Gas Purifiers


The MegaTorr PS6 Series Oxygen Gas purifiers sport an enhanced, optimized design providing sub ppb performance in a small footprint. SAES Pure Gas has drawn on years of experience in Ultra High Purity piping design, advanced process material analysis, and state of the art integrated control systems to develop a new family of purifiers to meet the needs of low capital cost, high reliability and high performance.
The PS6-MGT series produce ultra-high purity (UHP) gas for critical semiconductor applications. Through a combination of catalytic and adsorbtion processes, outlet impurity levels for CO, CO2, CH4, H2, and H2O are reduced to sub parts per billion (ppb) levels. Hydrocarbons (CH4), CO and H2 react at elevated temperatures with O2 in the oxidizing catalyst vessel to form CO2 and H2O which are then removed in the ambient temperature downstream adsorber vessels. The adsorber vessels alternate between purify and regeneration mode providing continuous purification. Adsorber regeneration is accomplished by backflushing with purified oxygen at elevated temperatures.

MegaTorr PS6 Oxygen Purifiers
ModelFlow RateDimensionsOutlet
PS6-MGT15-O15 Nm3/hr196 x 89 x 86 cm
77'' x 35'' x 34''
common to all:
H2O < 1 ppb
CO < 1 ppb
CO2 < 1 ppb
H2 < 1 ppb
CH4 < 1 ppb

contact factory
for further details
PS6-MGT30-O30 Nm3/hr196 x 89 x 86 cm
77'' x 35'' x 34''
PS6-MGT60-O60 Nm3/hr196 x 89 x 137 cm
77'' x 35'' x 54''
PS6-MGT100-O100 Nm3/hr196 x 89 x 137 cm
77'' x 35'' x 54''
PS6-MGT200-O200 Nm3/hr196 x 89 x 137 cm
77'' x 35'' x 54''

Standard Features:
  • Automated Microprocessor Controller
  • HMI (Human Machine Interface)
  • System Alarms
  • Gas to Gas Heat Exchanger
  • Electric Gas Preheaters
  • Closed-Loop Temperature Controls
  • All Metal Cabinet with Doors
Customer Interface Connections:
  • Alarm Relay - fail safe relay contacts allow remote detection of alarm condition.
  • Remote Contact Shutdown - allows remote shutdown of the purifier.
Optional Equipment:
  • Inlet & Outlet Isolation Valves
  • Mass flow meter with 4-20mA Output
  • Inlet & Outlet Pressure Transducers
  • Instrument Air Management System
  • Air Cooled Heat Exchanger
  • High Temperature Hardware Interlock
  • Over Pressurization Safety Relief System
  • Auto or Manual Bypass
  • Particle Filter
  • Separate Control Power
  • MODBUS Data Communication Port
© 2008 Rainer Lammertz